Agfa CR MD1.0General radiography CR plate and cassette line for MD1.0 workflows.Computed Radiography Cassettes
Agfa CR medical cassettes and imaging plates
Agfa CR medical cassettes protect reusable imaging plates during X-ray exposure, transport and handling, then route the exposed plate through Agfa CR digitizers and workstation processing.
Medem supplies the Agfa cassette lines already listed in our catalog: MD1.0, MD4.0, MD4.0T, MD4.0R, HD5.0, HM5.0, MM3.0T and MM3.0R.
Catalog models
Agfa cassette models listed by Medem
Agfa CR MD1.0General radiography CR plate and cassette line for MD1.0 workflows.
Agfa CR MD4.0General CR plate and cassette workflow for Agfa CR digitizers.
Agfa CR MD4.0TMD4.xT general cassette set, used with matching tray and image plate.
Agfa CR MD4.0RMD4.xR general plate and cassette line for routine CR imaging.
Agfa CR HD5.0HD5.x general detector/cassette family for general radiography and FLFS variants.
Agfa CR HM5.0HM5.x Mammo detector family for mammography CR workflows.
Agfa CR MM3.0TMM3.xT Mammo / extremities cassette family for dedicated high-detail applications.
Agfa CR MM3.0RMM3.xR Mammo plate and cassette line for mammography CR workflows.Types
How the Agfa CR cassette lines differ
MD1.0 and MD4.x — general radiography
Agfa MD cassettes protect the imaging plate during X-ray exposure, transport and handling, then the exposed plate is scanned by the CR digitizer.
HD5.x — general / FLFS / AEC detector family
HD5.x detectors are described by Agfa for general radiography, Full Leg Full Spine (FLFS) and AEC variants depending on the exact model.
HM5.x and MM3.x — mammography lines
Agfa HM and MM cassette/detector families are positioned for mammography or high-detail workflows and require correct matching plates and cleaning practice.
Matching plate and cassette matters
Agfa documentation stresses that the image plate dedicated to a cassette model should be used with the correct cassette/tray type.
Common sizes
Typical CR cassette formats
Large-format general radiography and chest workflow.
Square general radiography format where supported.
Routine diagnostic cassette size.
Smaller anatomy and focused CR workflow size.
Specialized panoramic / narrow-format workflow where supported.
Procurement
Supplier details for Agfa cassette buyers
Handling
Matching cassette and plate
- Use the image plate dedicated to the specific cassette model.
- Keep tray and plate sets matched where required by the cassette line.
- Use Agfa-approved cleaning practice for plate families and mammography plates.
- Confirm digitizer compatibility before ordering replacements.
Procurement support
Request Agfa CR cassette availability
Send cassette type, size, digitizer model, required quantity and destination. Medem will confirm availability and prepare a B2B offer.
FAQ
Agfa cassette buyer questions
What are Agfa CR medical cassettes?
Agfa CR cassettes hold and protect a reusable imaging plate during X-ray exposure, transport and handling. The exposed plate is read by an Agfa CR digitizer and routed through the workstation.
Which Agfa cassette lines does Medem list?
Medem lists existing catalog items MD1.0, MD4.0, MD4.0T, MD4.0R, HD5.0, HM5.0, MM3.0T and MM3.0R.
What is the price of Agfa CR cassettes?
The listed price is 950 EUR per cassette / detector set. Final availability depends on type, size and condition.
Can Agfa cassettes be used with any plate?
No. Agfa manuals emphasize using the image plate dedicated to the specific cassette/tray type. Mixing unmatched plates and cassettes is not recommended.
Which equipment is linked to Agfa cassettes?
Agfa CR cassette workflows are linked to CR digitizers such as CR 10-X, CR 15-X and CR 30-X, plus DRYSTAR film output when hardcopy is required.